Fire Pump Room Signage Requirements
Fire control room 19.
Fire pump room signage requirements. Section 10 1 2 5 2 has a requirement for electrical fire pumps systems when multiple pumps serve different areas or portions of the facility an appropriate sign must be conspicuously attached to each controller indicating the area zone or portion of the system served by that pump or pump controller. Non required stairs ramps escalators 21. And some local codes require riser rooms to house remote unit fire alarm panels connected to the master fire alarm panel in multi family residential occupancies. Fire detectors remote indicators 14.
The letters shall be of a color that contrasts with the. Exit directional signs 12. Fire p ump p ressures. A fire pump room sign has fdc messages for emergency response protocol and compliance.
From the 2016 edition of nfpa 13. Hard suction storz connection 23. For fire pumps such as horizontal split case and vertical in line centrifugal pumps that are required to operate under net positive suction head the total head of a fire pump is calculated by adding the suction head city pressure to the. Fire pump room sign brushed aluminum aluminum signs 3 5x8 the mont argent line 10.
Nfpa 20 provides for protection of the fire pump equipment as well as for personnel that need to access the fire pump equipment during a fire situation. 8 mm when located inside a building and 4 inches 101. Unless more stringent requirements apply lettering for signs required by this section shall have a minimum height of 2 inches 50. Section 6 6 4 of nfpa 13 stipulates sign requirements for all control drain venting and test connection valves while section 8 16 1 1 expands on the guidance for control valves.
While nfpa 20 requires that access to the fire pump room be pre planned with the fire department it now requires that the location of the fire pump room also be pre planned. We at hpd signs nyc provide all fire pump signage water pump signage for you building. A fire pump room sign is a useful tool to help protect the health and safety of staff and is not a substitute for necessary protective measures for lessening or eliminating hazards. 6mm when located outside or as approved by the fire code official.
In some instances the system s fire pump and fire alarm control panel are also located in the sprinkler riser room and additional signage is required if they are. Gaseous fire extinguishing systems 22. Most fire sprinkler system valves must be identified with metal or rigid plastic signs. The total head of a fire pump is the energy imparted to the liquid as it passes through the pump usually expressed in psi.
High voltage installations 16.